Blaze offers micro gas turbines for distributed power and CCHP applications. Our 20 kW model is designed for compact commercial, remote, and modular energy systems, while the 150 kW model serves industrial facilities, data centers, hospitals, and oilfields. A 500 kW model is currently under development for larger industrial and distributed energy projects. The portfolio delivers reliable on-site electricity, useful exhaust heat, multi-fuel flexibility, and scalable deployment.

| Parameter | Unit | 20kW Simple Cycle | 20kW Recuperated Cycle |
| Electrical Power Output | kW | 20 | 17 |
| Electrical Efficiency | % | 12 | 23 |
| Output Voltage | VAC | 400-480 | 400-480 |
| Output Frequency | Hz | 50 | 50 |
| Electrical Service | – | 3-phase, 4-wire | 3-phase, 4-wire |
| Fuel Input | Mj/h | 537 | 255 |
| Fuel Inlet Pressure | bar(g) | 4-5 | 4-5 |
| Exhaust Gas Flow | kg/h | 720 | 720 |
| Exhaust Gas Temperature | ℃ | 570 | 257 |
| Parameter | Unit | 150kW Simple Cycle | 150kW Recuperated Cycle |
| Electrical Power Output | kW | 151.8 | 129.9 |
| Electrical Efficiency | % | 16.7 | 30.5 |
| Output Voltage | VAC | 400-480 | 400-480 |
| Output Frequency | Hz | 50 | 50 |
| Electrical Service | – | 3-phase, 4-wire | 3-phase, 4-wire |
| Fuel Input | Mj/h | 3,265 | 1,533 |
| Fuel Inlet Pressure | bar(g) | 4-5 | 4-5 |
| Exhaust Gas Flow | kg/h | 4,094 | 4,059 |
| Exhaust Gas Temperature | ℃ | 610 | 250 |
| Steam Production | kg/h | 880 at 0.8 MPa | 200 at 0.2 MPa |
| Cooling Capacity | kW | 815 | 155 |
| Package Dimensions | mm | 1,650*2,150*2,135 | 1,650*2,150*2,700 |