The Frame 9F DLN combustion liner provides the passage between the designated head-end hardware and downstream connections. Its cylindrical body, formed end sections and outlet retention region are defined by the selected 9F DLN revision.



| Item | Required definition |
|---|---|
| Reference family | Frame 9F |
| Combustion configuration | Frame 9F, DLN liner; selected revision required |
| Component group | Combustion Liners |
| Geometry to define | Inlet profile, formed body sections, outlet retention region and specified internal surfaces |
| Mating references | Selected 9F DLN head-end and downstream connections |
| Material specification | Customer-defined grade and product form, confirmed during technical review |
| Manufacturing basis | Selected part drawing, revision and agreed acceptance requirements |
Review the inlet profile and formed body sections with the outlet retention region. Any specified internal surface requirements belong in the same technical definition. Blaze checks the liner against its mating head-end and downstream references before establishing the requested manufacturing and acceptance scope.
For the Frame 9F DLN Combustion Liner, the wall construction, openings and end features determine the proposed manufacturing route. Blaze reviews the forming, joining and finishing requirements stated in the drawing package before confirming the selected work. Material grade, product form and dimensional acceptance requirements must be specified; a coating or additional test is included only when defined in the project scope.
Yes, where the project specifies them. Include the relevant drawing notes and acceptance requirements with the inlet, body and outlet definitions; no default internal-surface specification is stated here.
No service-life figure is stated for this product. The enquiry defines manufacturing requirements for a selected component revision; operating-life claims require separate supporting evidence.
Send the part drawing and revision, known part number, material specification, quantity and inspection requirements. Include the DLN revision and any specified internal-surface requirements. If documentation is incomplete, include photographs and describe the available sample so Blaze can assess the next review step.
View Combustion Parts by Frame series
Frame and combustion-configuration names identify reference families. They do not establish OEM authorization or interchangeability. Fit is confirmed against the selected drawing revision and mating interfaces.